CICS

Syndicate content CICS Transaction Server
The latest updates about CICS Transaction Server
Updated: 1 hour 10 min ago

Copying CICS TS Java directory usr/lpp/cicsts for testing purposes

Thu, 2010-09-02 09:40
Can you copy the CICS Transaction Server for z/OS (CICS TS) Java directories from usr/lpp/cicsts to another directory so that you can apply maintenance and test the changes before putting the maintenance into production? Is possible for the CICS runtime to use a copy of the CICS HFS structure?
Categories: Geeky News

PM18482: CICS IS NOT WRITING THE CORRECT RBA IN THE WRITE-UPDATE (82) RECORDS FORWARD RECOVERY LOG FOR AN EXTENDED ESDS

Thu, 2010-09-02 01:00
If the record ends up in a new CI then the original write add (UNDO record) for backout will have an incorrect RBA, but the
Categories: Geeky News

PM16899: ABEND0C1 AFTER APPLYING APAR PK91585 TCB SWITCH NOT TAKING PLACE 10/06/23 PTF PECHANGE

Thu, 2010-09-02 01:00
Bug in code against APAR PK91585. The last change mode below, should have switched back to the QR
Categories: Geeky News

PM15622: CPSM API TPARSE TO FORMAT SCLOCK12 CPUTIME IN THE TASK TABLE FORMATS INCORRECTLY.

Thu, 2010-09-02 01:00
You are using a REXX program with the CPMS API to produce a filtered report of all non C* tasks in the
Categories: Geeky News

PM17952: ABENDAPIL ABEND0C4 IN DFHPISN +X'5CB4' AFTER APPLYING UK56502 WHEN CICS IS A WEBSERVICE REQUESTER. 10/07/07 PTF PECHANGE

Thu, 2010-09-02 01:00
CICS TS 3.2 after applying UK56502 (PM05868) and EXEC CICS INVOKE WEBSERVICE command leads to ABENDAPIL.
Categories: Geeky News

PM18431: CICS IS NOT WRITING THE CORRECT RBA IN THE WRITE-UPDATE (82) RECORDS FORWARD RECOVERY LOG FOR AN EXTENDED ESDS

Thu, 2010-09-02 01:00
If the record ends up in a new CI then the original write add (UNDO record) for backout will have an incorrect RBA, but the
Categories: Geeky News

PM16131: ABEND0C1 AFTER APPLYING APAR PK91585 TCB SWITCH NOT TAKING PLACE 10/06/23 PTF PECHANGE

Thu, 2010-09-02 01:00
Bug in code against APAR PK91585. The last change mode below, should have switched back to the QR
Categories: Geeky News

PM19003: DFH$UMOD TRIES TO MOVE DFHSJCSL TO SYSLIB(SDFJLPA) BUT SDFJLPA WAS REMOVED AT CTS 4.1.

Thu, 2010-09-02 01:00
You are installing CICS TS 4.1 and job DFH$UMOD tries to MOVE load module DFHSJCSL to SYSLIB(SDFJLPA). SYSLIB(SDFJLPA) has
Categories: Geeky News

PM16522: NODATA CONDITION ON NEWCOPY PHASEIN

Thu, 2010-09-02 01:00
A NODATA condition is being returned on a NEWCOPY PHASEIN. The program for the newcopy is missing from the hardened resource
Categories: Geeky News

PM16451: NODATA CONDITION ON NEWCOPY PHASEIN

Thu, 2010-09-02 01:00
A NODATA condition is being returned on a NEWCOPY PHASEIN. The program for the newcopy is missing from the hardened resource
Categories: Geeky News

PM19470: SEVERAL EYUXL0905E ERRORS FOR ASRA IN NQDC - ABEND 0C1

Thu, 2010-09-02 01:00
Abends 0C1 ASRA are issued repeatedly in NQDC with the following psw and regs:
Categories: Geeky News

PM13290: END CONTENT IN ATOM FEED IS INCORRECT 10/07/19 PTF PECHANGE

Thu, 2010-09-02 01:00
The problem is that in the feed produced, the end content tag is coming out wrong, often La.......n.%
Categories: Geeky News

PM17228: EXTEND UEFDTBL TO ALSO REFLECT CICS MAINTAINED DATA TABLES.

Thu, 2010-09-02 01:00
User exit fields UEFDTBL and UEFDTUM were provided for global user exits XFCSREQ and XFCSREQC. These new fields were
Categories: Geeky News

PM15216: ABENDARZ5 WHEN PROCESSING A CORBA REQUEST STREAM . 10/05/26 PTF PECHANGE

Thu, 2010-09-02 01:00
All requests from a Corba Server fail with abendARZ5 if the TCPIPSERVICE for IIOP specifies a URM . (The URM for a
Categories: Geeky News

PM18842: PROVIDE C VARIANT OF DFHMNTDS

Thu, 2010-09-02 01:00
Provide C variant of DFHMNTDS
Categories: Geeky News

PM16633: DFHNQ0002 X'0212' FOR EXTENDED, RECOVERABLE ESDS FILES

Thu, 2010-09-02 01:00
CICS emergency restart fails with: DFHNQ0002 A severe error (code X'0212') has occurred in module
Categories: Geeky News

PM18974: LOOP IN DFHCFCFN MODULE WHEN ELEMENTWARN AND ENTRYWARN PARM OF CFDT SERVER ARE SET TO A LOWER VALUE THAN THE ACTUAL.

Thu, 2010-09-02 01:00
A loop condition with an high CPU consumption is detected in DFHFCMN , the Coupling Facility Data Table CFDT server .
Categories: Geeky News

PM15381: ASSIGN INVOKINGPROG() COMMAND IN CSQCAPX RETURNS BLANKS

Thu, 2010-09-02 01:00
After PK70901, an EXEC CICS ASSIGN INVOKINGPROGRAM () command in the MQ crossing exit, CSQCAPX returns blanks rather than the
Categories: Geeky News

PM19096: EYUVC1231E 'CREATE' (CREATE) REQUEST FAILED. (TABLEERROR, DATAERROR) WHEN CREATING A SYSLINK

Thu, 2010-09-02 01:00
You have a number of connections and sessions defined in your CICSPlex. When you use the WUI to create a SYSLINK you get
Categories: Geeky News

PM19090: EYUVC1231E 'CREATE' (CREATE) REQUEST FAILED. (TABLEERROR, DATAERROR) WHEN CREATING A SYSLINK

Thu, 2010-09-02 01:00
You have a number of connections and sessions defined in your CICSPlex. When you use the WUI to create a SYSLINK you get
Categories: Geeky News

MyMusic

Flickr recent photosets

Solent sailMy Music